F.A.Q. по ремонту и обслуживанию копиров

The surface temperature of the




Код ошибки

Описание

E000

The surface temperature of the fixing assembly upper roller fails to rise by a specified value within 90 sec after power-on. The surface temperature of the fixing assembly upper roller fails to reach 150C within 8 min after power-on

E001

The surface temperature of the fixing assembly upper roller exceeds 250C

E005

The cleaning belt inside the fixing assembly has been taken up more than a specified length

E010

After generation of the main motor drive signal, two or more pulses are not received within 2 sec

E013

The error detection circuit on the waste toner feed motor driver PCB has detected an overcurrent

E020

The accumulative time during which the toner supply signal (TSP) has been generated by the developing assembly reaches 3 min*

E050

The holding tray home position signal (THP) is not generated within 4 sec while the holding tray motor drive signal (TMDP1, 2) is being generated. The holding tray home position signal (THP) is generated 1 sec or more while the holding tray motor drive signal (TMDP1, 2) is being generated

E203

Input of two or more clock pulses is not received within 2 sec from the scanner motor drive signal is generated

E210

The lens home position signal (LHP) is not generated within 4.8 sec after power switch or door switch has gone ON. The lens home position signal (LHP) is generate 2 sec or more

E240

An error has occurred in the microprocessor on the DC controller PCB

E243

An error has occurred in the microprocessor of the DC controller PCB and the microprocessor in the control panel

E710

An error has occurred in the communication between the DC controller PCB and the controller PCB of the option, and the DC controller has detected the error

E712

No communication is perceived from the RF controller PCB for 200 ms or more the communication is monitored at all times